Canada

Other Sites in English

VZ401 Touchscreen Firmware Update

NOTE: DO NOT use this update on a VX401, please use the VZ401 update ONLY.

Firmware update to prevent loss of touch screen calibration

Precautions:

Do not power off the unit while performing any portion of this update unless specifically instructed.

Do not operate the unit while performing any portion of this update unless specifically instructed.

If you are not comfortable with any of the procedures below, please contact the Clarion dealer from which you purchased the unit for assistance.

NOTE: If your VZ401 has lost the touch screen calibration, follow the calibration procedure below BEFORE doing the update.

Touch Screen Calibration Procedure

a) Turn on the VZ401

b) Using the IR Remote control, press the Menu Button

c) TUNER should be highlighted in Blue

d) Press the right arrow until the 'Settings' tab is highligted

e) Press ENT on the remote

f) The Clock tab will be highlighted

g) Press the down left arrow to highlight the General Tab

h) press the down arrow to highlight the Monitor Adjust Tab

i) Press Enter

j) TS Calibrate should be highlight, press ENT

k) Press the down arrow to highlight 'Yes', then press Enter

l) Follow the instructions on the screen to perform the calibration

note: If the touch screen calibration procedure repeats itself, use your fingernail to touch each blue square to provide a more accurate calibration point

Touch Screen Calibration Update Installation Procedure:

Step 1

a) Download "VZ401ts_082712.zip"

 

b) Save file to your computer

c) Insert a blank USB memory stick into your computer

d) Using Winzip (or similar), extract the contents of VZ401ts_082712.zip to your computer

e) Copy build.img and update.ver to the root of the blank USB memory Stick

Step 2

a) Ensure that the VZ401 is turned off

b) Insert the USB stick into the rear USB port of the VZ401

c) Turn on the VZ401

d) Select 'Back' to go to the main menu

e) Select USB

f) You will see a screen titled 'Loading" with a window that says "Firmware Upgrade"

g) Tap the MPEG button

f) You will see a screen titled 'Loading

h) The screen will now say MPEG Firmware Upgrade

h) The screen will now say MPEG Firmware Upgrade

i) Once done, the Clarion logo screen will be displayed

j) Press and hold the SRC button to turn the unit off

k) Remove the USB Memory Stick

l) Turn the vehicle ignition off

m) Using the tip of a pen or a paperclip, press and hold the reset button on the face of the unit for 5 seconds

n) turn the vehicle ignition on

o) Turn the VZ401 on by touching the SRC button

Step 3

w) Tap the 'back' button to get to the main menu

x) Tap the 'settings' icon

y) Tap the 'version' button

z) Confirm the software versions

MCU: 2.8.16_0163_101115

MPEG: 1.3.11_0154_120302

Servo: F/E:D04.02.081110

Return to the top of the page